Bosch Dishwasher E:11: Heat Pump Temperature Sensor Out of Range
E:11 shows on Bosch dishwashers such as the SHEM63W55N, SHEM63W52N and SHEM63W56N when the heat pump's temperature sensor readings are out of range. The far right LED flashes. Bosch's check measures the sensor between pump terminals,…
- Code
- E:11
- Appliance
- Dishwasher
- Brand
- Bosch
- Warranty
- 30-day workmanship
What E:11 means
E:11 shows on Bosch dishwashers such as the SHEM63W55N, SHEM63W52N and SHEM63W56N when the heat pump's temperature sensor readings are out of range. The far right LED flashes. Bosch's check measures the sensor between pump terminals, which should read about 10 kOhm on two pairs and about 20 kOhm across the outer pair at room temperature. The temperature sensor sits inside the heat pump.
Common causes of E:11
- Heat pump temperature sensor reading out of range
- Damaged or loose wiring between the heat pump and power module
- Heat pump needs replacement
1. Turn the dishwasher off at the breaker, wait a minute, then restore power. 2. Run a short cycle. 3. If E:11 appears again, leave the machine off. 4. Do not open any panels; the sensor readings are taken at the pump terminals and need a meter.
- The sensor sits inside the heat pump assembly, so readings must be taken at its connector.
- Correct readings depend on knowing the model's published values.
- If the wiring is sound and the readings are off, the heat pump itself is replaced.
Technical reference
- Code
- E:11
- Appliance
- Bosch dishwasher
- Maker documentation
- Bosch owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Bosch.
Other Dishwasher codes
What is the sensor measuring?
It reads water temperature at the heat pump so the control can regulate heating. When its resistance falls outside the expected range, the control reports E:11. Because the reading changes with temperature, we compare it against the published room-temperature values for the model.
Could it be just a loose wire?
Yes, which is why we check the harness before replacing the pump. A loose connection can mimic a failed sensor. Loose wiring is common and cheap to fix, so that comes first in our check.
Do I need to describe the readings to you?
No. Just tell us the model and code. We take the measurements, quote in writing first, and warrant the work for 30 days. Our technician will bring the model's published values to compare against.
Still seeing E:11?
A technician diagnoses it on site and gives you the price in writing before any work starts.