Bosch Washer dr:06: Inverter Overheating Protection
dr:06 is a Vision 16 WFVC inverter code; the manual names no US E-Nr, and it has no counterpart on Nexxt or current WAT, WAW, and WAP washers. Bosch lists it as an NTC-relay failure: the…
- Code
- dr:06
- Appliance
- Washer
- Brand
- Bosch
- Warranty
- 30-day workmanship
What dr:06 means
dr:06 is a Vision 16 WFVC inverter code; the manual names no US E-Nr, and it has no counterpart on Nexxt or current WAT, WAW, and WAP washers. Bosch lists it as an NTC-relay failure: the inverter's temperature sensor reads too hot, or its relay is stuck. The remedy is to wait a couple of minutes and, if it stays, replace the inverter.
Common causes of dr:06
- Inverter temperature sensor reading too hot after heavy use
- Inverter relay stuck
- Inverter control damaged
1. Press Off and let the washer rest for a few minutes. 2. Make sure the area behind the washer is clear and the room is not very hot. 3. Restart a short cycle. 4. If dr:06 repeats, stop, unplug the washer, and call us. Do not open the cabinet to inspect the drive.
- A hot inverter that repeats the code is not just resting; a stuck relay or damaged board is a real possibility.
- Opening the cabinet to look at the inverter is not safe for owners.
- We give the price in writing before we replace anything.
Technical reference
- Code
- dr:06
- Appliance
- Bosch washer
- Maker documentation
- Bosch owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Bosch.
Other Washer codes
Does waiting really help?
Yes. If the inverter was simply hot, a few minutes of rest lets it cool and the code can clear. If it comes right back, something else is wrong.
Could heavy loads cause this?
They can raise the inverter's temperature, but Bosch also lists a stuck relay. Repeated heat-trips mean we should inspect it. Hot rooms and blocked airflow behind the washer do not help either.
Is this the same as Er:05?
No. Er:05 is the wash-water temperature sensor. dr:06 is the inverter's own thermal protection. Er:05 concerns the water sensor. dr:06 is about electronics heating up, so the fixes are different.
Still seeing dr:06?
A technician diagnoses it on site and gives you the price in writing before any work starts.