Booking today · Houston service windows 8–10 · 10–12 · 12–2 · 2–4 Independent Bosch specialists · Licensed & insured Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(713) 568-9298 Schedule a Visit
Error code · Range

Bosch Range E302 Warns That the Control Board Is Too Hot

A hot control board is the story behind E302. The module's built-in sensor measured heat above its limit, so oven heating stopped and the cooling fan jumped to full speed. Normal operation returns once the cavity…

High · stop use, call now
Code
E302
Appliance
Range
Brand
Bosch
Warranty
30-day workmanship

What E302 means

A hot control board is the story behind E302. The module's built-in sensor measured heat above its limit, so oven heating stopped and the cooling fan jumped to full speed. Normal operation returns once the cavity falls to 212 degrees Fahrenheit. A self-clean already underway stays blocked until the control is reset, Bosch notes, since that cycle loads the appliance with more heat than anything else it does.

Common causes of E302

  • Fan that has stopped or is turning slowly
  • Ventilation trim that is blocked or damaged
  • Heating relay stuck on, pushing extra heat into the control area
✓ One safe check you can try

1. Turn the oven off and give the range time to cool. 2. Look at the vent trim above the oven door: it must be clear, undamaged and uncovered; at counter height a towel or tray is enough to block it. 3. Restore power and use the range lightly. 4. If E302 returns, call us rather than running more cycles.

! Why to stop there
  • Running the oven again before the cause is known keeps stressing a board that just reported overheating.
  • A stopped fan gives no warning until the board overheats, and a new board will not bring the fan back.
  • A relay stuck closed is a safety matter, not a home test.
Opening a panel yourself does not automatically cancel a manufacturer warranty, but it can cause accidental damage, and some manufacturers set their own service conditions. Check your warranty terms, or ask us, before deciding.
→Same appliance

Other Range codes

E302E302 questions
It recovered on its own; are we done?

It restarted by design once the cavity cooled to 212 degrees Fahrenheit, but whatever overheated the board has not been fixed, so expect a repeat. Mention how often it happens when you call.

Why won't self-clean start afterward?

Bosch blocks it until a control reset is done, because cleaning generates the most heat of any cycle and the board has just shown it struggled.

Can clutter near the oven trigger it?

Yes. A blocked vent trim is one of Bosch's listed causes, so keeping the strip above the door clear is a simple preventive step. Wipe away crumbs and grease there occasionally as well.

Book a visit

Still seeing E302?

A technician diagnoses it on site and gives you the price in writing before any work starts.

☎ Call the desk ▤ Schedule a Visit