Error code · Coffee Machine

Bosch Coffee Machine Error 1: Temperature Sensor Out of Range

On the Bosch TCA6 Automatic Coffee Center, including the TCA6001UC and TCA6301UC, Error 1 shows with the upper symbol lit and the lower row flashing. The NTC temperature sensor is outside its measurement range, so the…

Medium · inspection needed
Code
Error 1
Appliance
Coffee Machine
Brand
Bosch
Warranty
30-day workmanship

What Error 1 means

On the Bosch TCA6 Automatic Coffee Center, including the TCA6001UC and TCA6301UC, Error 1 shows with the upper symbol lit and the lower row flashing. The NTC temperature sensor is outside its measurement range, so the machine cannot judge water temperature and stops brewing. This is an older numbered-error generation; newer Bosch machines show plain-language messages instead. Brewing resumes once the reading is back in range.

Common causes of Error 1

  • NTC temperature sensor out of measurement range
  • Sensor wiring or connector problem
✓ One safe check you can try

1. Switch the machine off with its power switch and unplug it for ten minutes. 2. Plug it back in and let it start up. 3. Try one brew. 4. If Error 1 returns, stop and call us. Do not open the housing; the sensor and its wiring sit inside the heating area, next to mains-powered parts.

! Why to stop there
  • The sensor is part of the heating system inside the housing.
  • Resistance and wiring tests are needed to decide between sensor and wiring.
  • Opening the machine exposes mains power.
Opening a panel yourself does not automatically cancel a manufacturer warranty, but it can cause accidental damage, and some manufacturers set their own service conditions. Check your warranty terms, or ask us, before deciding.

Technical reference

Code
Error 1
Appliance
Bosch coffee machine
Checked
October 2026

We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Bosch.

Error 1Error 1 questions
What is an NTC sensor?

It is a temperature sensor whose resistance changes with heat. The control reads it to keep the brewing water at the right temperature, so a reading outside its range stops the machine.

Can descaling fix Error 1?

The service text points to the sensor and its wiring, not to scale, so descaling is unlikely to clear it. Scale is not named as a cause for this error.

What does service involve?

We test the sensor and the wiring to it, replace what has failed, and give you a written price before any work. Our workmanship on this repair is warranted for 30 days.