Bosch Coffee Machine Empty Trays: Dregs Drawer or Drip Tray Full
On the Bosch TCA6 Automatic Coffee Center, including the TCA6001UC and TCA6301UC, EMPTY TRAYS appears when the dregs drawer or drip tray is full. The machine detects tray insertion and fill through contacts that sense water,…
- Code
- Empty Trays
- Appliance
- Coffee Machine
- Brand
- Bosch
- Warranty
- 30-day workmanship
What Empty Trays means
On the Bosch TCA6 Automatic Coffee Center, including the TCA6001UC and TCA6301UC, EMPTY TRAYS appears when the dregs drawer or drip tray is full. The machine detects tray insertion and fill through contacts that sense water, so dirty contacts can trigger the message even when the trays are not full. Emptying and cleaning is the first step. Rinse, dry and refit.
Common causes of Empty Trays
- Dregs drawer or drip tray full
- Dirty tray contacts
- Tray not seated correctly
1. Switch the machine off. 2. Remove the drip tray and dregs drawer and empty them. 3. Rinse and dry them, then wipe the contact area with a damp cloth and dry it. 4. Reinsert the trays fully. 5. Switch on, and call us if the message remains.
- The contacts connect to the control inside the housing.
- Corrosion on contacts is hard to judge visually.
- We clean and test them as part of the visit.
Technical reference
- Code
- Empty Trays
- Appliance
- Bosch coffee machine
- Maker documentation
- Bosch owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Bosch.
Other Coffee Machine codes
What are the tray contacts?
They are small metal points that detect that the tray is in place and whether it holds water. Residue or moisture on them can make the machine think a tray is full.
Why does it say empty trays when they are empty?
Dirty contacts can read as a full tray. A thorough clean and dry wipe often clears the message, and it costs nothing to try. Use a soft cloth.
What does a visit include?
We clean and test the contacts and the holder, give you a written price before work, and warrant any repair for 30 days after the visit.
Still unsure about Empty Trays?
A technician diagnoses it on site and gives you the price in writing before any work starts.