Bosch Refrigerator rt: Room Temperature Sensor Problem
The code rt on Bosch 800 and 500 Series Evolution refrigerators such as the B26FT70SNS and B26FT70SNS/01 means the room, or ambient, temperature sensor reads Lo or Hi. Bosch checks it at connector CN15 on the…
- Code
- rt
- Appliance
- Refrigerator
- Brand
- Bosch
- Warranty
- 30-day workmanship
What rt means
The code rt on Bosch 800 and 500 Series Evolution refrigerators such as the B26FT70SNS and B26FT70SNS/01 means the room, or ambient, temperature sensor reads Lo or Hi. Bosch checks it at connector CN15 on the main board. The refrigerator uses that reading to adapt its cooling to the kitchen around it, so a bad sensor causes small shifts in performance instead of a sudden failure.
Common causes of rt
- Room temperature sensor has failed
- Loose connector at CN15
- Damaged sensor wire
1. Check that the refrigerator has clearance around it for air to move. 2. Keep it away from ovens, dishwashers venting steam, or direct sunlight. 3. Unplug it for five minutes, then plug it back in. 4. Leave the temperature settings unchanged. 5. If rt returns, call us when convenient; it is a lower-priority sensor code.
- The sensor is inside the cabinet and wired to the main board.
- The reading may be affected by a hot kitchen as well as a failed sensor.
- Only a board-level check tells which.
Technical reference
- Code
- rt
- Appliance
- Bosch refrigerator
- Maker documentation
- Bosch owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Bosch.
Other Refrigerator codes
Is rt urgent?
Usually less urgent than the compartment sensor codes, because it adjusts cooling to the kitchen instead of controlling one compartment. We still recommend a check so the code does not hide other problems.
Can a hot kitchen set rt off?
The code reports the sensor reading as Lo or Hi, meaning outside its normal range, not simply a warm room. A reading outside that range points to the sensor or its connection.
What will you check?
We test the room sensor at connector CN15, replace it if it reads out of range, and confirm the code clears. You get a written price first and a 30-day workmanship warranty.
Still unsure about rt?
A technician diagnoses it on site and gives you the price in writing before any work starts.