Bosch Refrigerator r3 Shows a Fresh Food Defrost That Timed Out

Think of r3 as the fresh food version of the freezer defrost problem. The defrost cycle for that evaporator reached its fifty-minute limit and the coil never got warm enough to end it normally. The manual's…

Medium · inspection needed
Code
r3
Appliance
Refrigerator
Brand
Bosch
Warranty
30-day workmanship

What r3 means

Think of r3 as the fresh food version of the freezer defrost problem. The defrost cycle for that evaporator reached its fifty-minute limit and the coil never got warm enough to end it normally. The manual's check is the resistance of the fridge defrost heater, assembled together with that evaporator. Over several days the fresh food section quietly loses its chill.

Common causes of r3

  • Fresh food defrost heater that has failed open
  • Defrost circuit thermostat or fuse that is open
  • Heater wiring damaged at the evaporator
✓ One safe check you can try

1. Think back over the last few days: has the fresh food section been losing its chill while the freezer seemed fine? 2. Look under the crisper drawers for pooled water. 3. Both fit this code. Wipe up any water, keep a thermometer inside, and call us.

! Why to stop there
  • Mopping up water without finding the source lets it return and may reach electrical parts.
  • Heater, thermostat and fuse failures look alike without testing.
  • Waiting lets ice build up on the evaporator, which reduces airflow.
Opening a panel yourself does not automatically cancel a manufacturer warranty, but it can cause accidental damage, and some manufacturers set their own service conditions. Check your warranty terms, or ask us, before deciding.
→Same appliance

Other Refrigerator codes

r3r3 questions
What does the fifty minutes refer to?

It is the maximum length of the defrost cycle. When the coil has not reached the end temperature in that time, the cycle stops and the control sets r3.

Why is there water under my crisper drawers?

Poor defrosting can leave meltwater with nowhere to go, or ice that melts later. It is a common companion of this code. Waiting only lets the ice thicken.

Is r3 urgent?

Moderately so. Food may stay safe for a while, but the problem only gets worse. We would book a visit soon so the evaporator does not ice over.

Book a visit

Still seeing r3?

A technician diagnoses it on site and gives you the price in writing before any work starts.