No heat, and a simple restart may not rescue it: E126 means the control no longer receives the signal from the switch that reports the door latch's position. If the range cannot tell whether the door…
No heat, and a simple restart may not rescue it: E126 means the control no longer receives the signal from the switch that reports the door latch's position. If the range cannot tell whether the door is locked, Bosch disables every heating element, and its manual says only a software reset clears the error. The listed checks are the switch plugs, the wiring running back to the control, and the switch itself.
1. Shut off the breaker for two minutes; the manual calls for this reset. 2. Bring power back and see if the range recovers. 3. Pay attention to whether the code returns instantly or stays away, because that separates a one-time glitch from a dying switch. 4. Leave the latch assembly alone.
The others log a latch that fails to move. This one logs a control that has lost track of where the latch is, so it disables heating instead of retrying.
The reset clears the code, as the manual says, but it will not repair a dead switch or a broken wire. A code that comes back means the physical problem still needs attention.
While the error is active, heating elements are disabled, which on an electric range includes the surface. Gas burners often still work, but ask us before relying on them.
A technician diagnoses it on site and gives you the price in writing before any work starts.