On Bosch 800 and 500 Series Evolution refrigerators such as the B26FT70SNS and B26FT70SNS/04, FD means the freezer defrost sensor on the evaporator reads Lo or Hi. It is checked at connector CN15 on the main…
- Code
- FD
- Appliance
- Refrigerator
- Brand
- Bosch
- Warranty
- 30-day workmanship
What FD means
On Bosch 800 and 500 Series Evolution refrigerators such as the B26FT70SNS and B26FT70SNS/04, FD means the freezer defrost sensor on the evaporator reads Lo or Hi. It is checked at connector CN15 on the main board. The Bosch table notes that the code clears automatically when the sensor reads normal again. Defrost cycles may start or stop at the wrong time while it persists.
Common causes of FD
- Freezer defrost sensor on the evaporator has failed
- Loose connector at CN15
- Damaged sensor wire
1. Look at the freezer's back wall for heavy frost, but do not scrape or chip it. 2. Keep the freezer door closed as much as possible so less moist air gets in. 3. Disconnect the refrigerator from power for five minutes and then restore it. 4. If FD returns, call us; the sensor sits on the evaporator behind a panel.
- The sensor is on the evaporator behind the freezer liner.
- Frost buildup can spread to the fans if ignored.
- Replacing the sensor is a small repair when diagnosed correctly.
Technical reference
- Code
- FD
- Appliance
- Bosch refrigerator
- Maker documentation
- Bosch owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Bosch.
Other Refrigerator codes
Why does FD sometimes disappear on its own?
Bosch states that it clears automatically when the sensor reads normal. If the sensor or its connection is marginal, the reading can drift in and out of range and the code comes and goes.
Why does frost matter here?
The defrost sensor tells the control when to start and stop defrosting. When it misreads, ice can build up on the evaporator and cooling slowly gets worse.
Is FD the same as rD?
No. FD belongs to the freezer evaporator, while rD belongs to the fresh food evaporator. They are separate sensors, and each is tested at its own connection.
Still seeing FD?
A technician diagnoses it on site and gives you the price in writing before any work starts.