Bosch Oven E122: The Upper Probe Reads Hotter than Allowed
For the HBLP451UC, HBLP651UC, HBL8451UC, HBL8651UC, HBN8451UC and related wall ovens, E122 says the cavity 1 meat probe sensor temperature is too high, which points to a probe or receptacle failure. The oven stops heating until…
- Code
- E122
- Appliance
- Oven
- Brand
- Bosch
- Warranty
- 30-day workmanship
What E122 means
For the HBLP451UC, HBLP651UC, HBL8451UC, HBL8651UC, HBN8451UC and related wall ovens, E122 says the cavity 1 meat probe sensor temperature is too high, which points to a probe or receptacle failure. The oven stops heating until the probe is removed. Owners find a roast cycle halted mid-way with the probe still plugged in. It often shows up halfway through a roast.
Common causes of E122
- Meat probe giving an impossible high reading
- Probe receptacle in the cavity wall failing
- Probe cable damaged by heat
1. Switch the oven off and let it cool. 2. Unplug the meat probe, which Bosch says allows heating to resume. 3. Reset power at the breaker for five minutes. 4. Bake with a regular timer and skip the probe until it is checked. If E122 appears with no probe connected, call us.
- A probe reading too hot may come from the probe or from the socket, and only testing separates them.
- Pulling a hot probe from a hot cavity risks burns, so cool the oven first.
- Running a roast on guesswork ruins food and does nothing to repair the receptacle.
Technical reference
- Code
- E122
- Appliance
- Bosch oven
- Maker documentation
- Bosch owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Bosch.
Other Oven codes
Why does heating stop while the probe is in?
The control treats an impossible probe reading as a warning and holds heating until the probe is removed. It is a protective response. Let the oven cool before you pull anything out.
Is E122 the opposite of E123?
Yes. E122 means the probe reads too high, E123 means it reads too low. Both lead to the same stop in heating. Use a timer for the roast until it is sorted.
How do we proceed?
We test the probe and the receptacle, quote the price in writing first, and cover the work with a 30-day workmanship warranty. The socket and a spare probe are both tested on site.
Still seeing E122?
A technician diagnoses it on site and gives you the price in writing before any work starts.